Author: Cook, G.
Paper Title Page
MOP032 One Dimensional Beam Position Monitor Prototype using Incoherent Cherenkov Diffraction Radiation 94
 
  • A.J. Clapp
    Royal Holloway, University of London, Surrey, United Kingdom
  • L. Bobb, G. Cook
    DLS, Oxfordshire, United Kingdom
  • P. Karataev
    JAI, Egham, Surrey, United Kingdom
 
  This paper proposes a novel advancement in both the studies of Cherenkov diffraction radiation (ChDR) and beam instrumentation. The proposed beam position monitor (BPM) consists of two identical fused Silica prism radiators, with a fibre collimator attached to each one, which in turn are connected to a photodetector via a series of optical fibres. The setup will be implemented into the booster to storage ring transfer line at Diamond Light Source ¿ an electron light source with 3 GeV beam energy. The prototype proposed aims to test the feasibility of a full BPM utilising ChDR. If proven to be fully realisable, optical rather than capacitive BPM pickups could be more widely distributed. The paper will include the complete design and preliminary results of a one-dimensional BPM, utilising the ChDR effect.  
poster icon Poster MOP032 [2.516 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-MOP032  
About • Received ※ 26 August 2023 — Revised ※ 07 September 2023 — Accepted ※ 14 September 2023 — Issue date ※ 27 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)