BiBTeX citation export for MO3C04: A MTCA Based BPM-System for PETRA IV

@inproceedings{kube:ibic2023-mo3c04,
  author       = {G. Kube and A. Bardorfer and L. Bogataj and M. Cargnelutti and H.T. Duhme and J.L. Lamaack and P. Leban and M.O. Oblak and P. Paglovec and B. Repič and F. Schmidt-Föhre and K. Wittenburg},
% author       = {G. Kube and A. Bardorfer and L. Bogataj and M. Cargnelutti and H.T. Duhme and J.L. Lamaack and others},
% author       = {G. Kube and others},
  title        = {{A MTCA Based BPM-System for PETRA IV}},
% booktitle    = {Proc. IBIC'23},
  booktitle    = {Proc. 12th Int. Beam Instrum. Conf. (IBIC'23)},
  eventdate    = {2023-09-10/2023-09-14},
  pages        = {19--23},
  paper        = {MO3C04},
  language     = {english},
  keywords     = {electron, brilliance, electronics, operation, controls},
  venue        = {Saskatoon, Canada},
  series       = {International Beam Instrumentation Conference},
  number       = {12},
  publisher    = {JACoW Publishing, Geneva, Switzerland},
  month        = {12},
  year         = {2023},
  issn         = {2673-5350},
  isbn         = {978-3-95450-236-3},
  doi          = {10.18429/JACoW-IBIC2023-MO3C04},
  url          = {https://jacow.org/ibic2023/papers/mo3c04.pdf},
  abstract     = {{The PETRA IV project aims to upgrade the present PETRA III synchrotron into an ultra low-emittance source. The small emittances translate directly into much smaller beam sizes, thus imposing stringent requirements on the machine stability. In order to measure beam positions and control orbit stability to the level of 10% of beam size and divergence, a high resolution BPM system will be installed which consists of 788 individual monitors with the readout electronics based on MTCA.4. In order to fulfil the long-term drift requirement (< 1 micron over 7 days), several analog, digital and SW parts were taken from the Libera Brilliance⁺ and a new RTM module has been developed to be used as BPM electronics RFFE. In addition, its analogue RF switch matrix used for long-term stabilization was separated and placed close to the BPM pickup, hence enabling an additional stabilization of the RF cables. At present, a fully populated MTCA crate with 6 AMC boards for the readout of 12 BPMs is installed at PETRA III and is extensively being tested. This contribution summarizes the latest beam measurements, demonstrating the high performance of the BPM system and the external stabilization concept.}},
}