Author: Voy, D.C.
Paper Title Page
MOPP33 BPM System for the PIP-II Injector Test Facility 133
 
  • N. Eddy, J.S. Diamond, B.J. Fellenz, R.R. Santucci, A. Semenov, D. Slimmer, D.C. Voy
    Fermilab, Batavia, Illinois, USA
 
  Funding: Work supported by the Fermi National Accelerator Laboratory, managed and operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the U.S. Department of Energy.
A new BPM system was used for commissioning and operation of the PIP2 Injector Test Facility. The system of 13 warm and 12 cold BPMs was based upon custom 250 MS/s digitizers controlled and readout over gigabit ethernet by a single multi-core rackmount server running linux. The system provided positions, intensity, and phase for each bpm as a pulse average or pulse waveform from 10 us to 4 ms at a 20 Hz pulse repetition rate.
 
poster icon Poster MOPP33 [1.712 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2021-MOPP33  
About • paper received ※ 10 September 2021       paper accepted ※ 17 September 2021       issue date ※ 10 October 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)