Paper |
Title |
Page |
TUPP14 |
Commissioning of the SEM-Grid Monitors for ELENA |
223 |
|
- M. McLean, J. Cenede, G. Tranquille
CERN, Meyrin, Switzerland
- M. Hori
MPQ, Garching, Munich, Germany
|
|
|
ELENA is a compact ring for cooling and further deceleration of 5.3 MeV antiprotons delivered by the CERN Antiproton Decelerator. It decelerates antiprotons to a minimum energy of 100 keV, creating special challenges for the beam instrumentation. These challenges have been addressed by an extremely sensitive SEM-Grid monitor which is also compatible with the UHV requirements of ELENA. Since November 2019 ELENA’s H− ion source has been used to test the SEM-Grid monitors and since July 2020 the monitors have been used to commission the ELENA transfer lines. In this paper a summary of the features of the SEM-Grid will be given, and an overview of the commissioning activities. A technique for testing the integrity of an inaccessible pickup wire will also be described.
|
|
|
Poster TUPP14 [0.405 MB]
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IBIC2021-TUPP14
|
|
About • |
paper received ※ 01 September 2021 paper accepted ※ 16 September 2021 issue date ※ 01 October 2021 |
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,