Paper | Title | Other Keywords | Page |
---|---|---|---|
MOPA09 | Overview of Beam Instrumentation and Commissioning Results from the Coherent Electron Cooling Experiment at BNL | electron, laser, optics, undulator | 43 |
|
|||
Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy The Coherent Electron Cooling (CeC) Proof-of-Principle experiment [1], installed in the RHIC tunnel at BNL, has completed its second run. In this experiment, an FEL is used to amplify patterns imprinted on the cooling electron beam by the RHIC ion bunches and then the imprinted pattern is fed back to the ions to achieve cooling of the ion beam. Diagnostics for the CeC experiment have been fully commissioned during this year’s run. An overview of the beam instrumentation is presented, this includes devices for measurements of beam current, position, profile, bunch charge, emittance, as well as gun photocathode imaging and FEL infra-red light emission diagnostics. Design details are discussed and beam measurement results are presented. [1] I. Pinayev, et al, ’First Results of Proof-of-Principle Experiment of Coherent Electron Cooling at BNL’ proceedings from IPAC 2018, Vancouver, CANADA |
|||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2018-MOPA09 | ||
About • | paper received ※ 04 September 2018 paper accepted ※ 12 September 2018 issue date ※ 29 January 2019 | ||
Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | ||