Paper | Title | Page |
---|---|---|
WEPA12 | Differential Evolution Genetic Algorithm for Beam Bunch Temporal Reconstruction | 392 |
|
||
Funding: Work supported by China National Natural Science Foundation of China with grant (11475159, 11505173, 11505174, 11575264, 11605190 and 11105019) Coherent radiation, such as coherent transition radiation, coherent diffraction radiation, coherent synchrotron radiation, etc, can be used to measure the longitudinal distribution of the electron beam bunch of any length, as long as the coherent radiation spectrum can be measured. In many cases, the Kramers-Krönig relationship is used to reconstruct the temporal distribution of the beam from the coherent radiation spectrum. However, the extrapolation of the low frequency will introduce the uncertainty of the reconstruction. In this paper, an algorithm of differential evolution (DE) for temporal reconstruction is discussed. The DE reconstruction works well for the complex and ultrashort distribution. It will be an effectIve tool to accurately measure the femtosecond bunch temporal structure. |
||
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2018-WEPA12 | |
About • | paper received ※ 07 September 2018 paper accepted ※ 13 September 2018 issue date ※ 29 January 2019 | |