Paper |
Title |
Page |
WEPC09 |
Design and Test Results of a Double-Slit Emittance Meter at XiPAF |
509 |
|
- M.W. Wang, X. Guan, W.-H. Huang, X.W. Wang, Q.Z. Xing, S.X. Zheng
TUB, Beijing, People’s Republic of China
- M.T. Qiu, D. Wang, Z.M. Wang, C.Y. Wei
NINT, Shannxi, People’s Republic of China
|
|
|
Xi’an Proton Application Facility (XiPAF) is composed of a linac injector, a 230-MeV synchrotron and a high energy transport line. To study the beam dynamics along beamline, a double-slit emittance meter is used to measure beam phase space in the linac. To have knowledge of phase space upstream of the emittance meter, an inverse transport method is proposed in the presence of space charge. The design and preliminary test results of the emittance meter are shown in this paper.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IBIC2018-WEPC09
|
|
About • |
paper received ※ 02 September 2018 paper accepted ※ 11 September 2018 issue date ※ 29 January 2019 |
|