Author: Fujita, T.
Paper Title Page
TUOC04 Development of Beam Position Monitor for the SPring-8 Upgrade 204
 
  • H. Maesaka
    RIKEN SPring-8 Center, Innovative Light Sources Division, Hyogo, Japan
  • H. Dewa, T. Fujita, M. Masaki, S. Takano
    JASRI, Hyogo, Japan
 
  We are developing a new electron beam position monitor (BPM) system for the low-emittance upgrade of SPring-8. The requirements for the BPM system are: (1) a single-pass resolution of 100 µm rms for a 100 pC bunch and an electric center accuracy of 100 µm rms for the initial beam commissioning to achieve the first turn, (2) a closed-orbit distortion (COD) resolution better than 0.1 µm rms for a 100 mA stored beam and a position stability of less than 5 µm for the ultimate stability of a photon beam axis. We have completed prototypes of a precise button electrode and a BPM block to obtain high-intensity signals and sufficient mechanical accuracy while suppressing high-Q trapped modes leading to impedance and heating issues. The development of readout electronics based on the MTCA.4 standard and the evaluation of radiation-hard coaxial cables have also been conducted. The prototype BPM head was installed in the present SPring-8 storage ring for performance verification with an actual electron beam. We confirmed sufficient signal intensity, electric center accuracy, position stability, etc. by the beam test. The new BPM system is almost ready for the SPring-8 upgrade.  
slides icon Slides TUOC04 [2.126 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2018-TUOC04  
About • paper received ※ 06 September 2018       paper accepted ※ 12 September 2018       issue date ※ 29 January 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)