Author: Cogan, S.
Paper Title Page
TUPC07 First Results of Button BPMs at FRIB 311
 
  • S. Cogan, J.L. Crisp, T.M. Ford, S.M. Lidia
    FRIB, East Lansing, USA
 
  Funding: This material is based upon work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC0000661, the State of Michigan and Michigan State University.
Commissioning and tuning the linac driver for the Facility for Rare Isotope Beams (FRIB) requires a large network of warm and cryogenic BPMs, with apertures of 40 - 150 mm, sensitivity to beam currents of 100 nA to 1 mA, and accurate for beams with velocities as low as 0.03c. We present initial results of the BPM system, analog and digital signal processing, distortion and error correction, and calibration for time of flight (TOF) measurements. Measurements for low energy beams are presented.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IBIC2018-TUPC07  
About • paper received ※ 13 September 2018       paper accepted ※ 20 November 2018       issue date ※ 29 January 2019  