RIS citation export for TUPG38: A PPS Compliant Stored Beam Current Monitor at NSLS-II

TY - CONF
AU - Caracappa, A.
AU - Danneil, C.
AU - Della Penna, A.J.
AU - Fliller, R.P.
AU - Padrazo, D.
AU - Singh, O.
ED - Schaa, Volker RW
TI - A PPS Compliant Stored Beam Current Monitor at NSLS-II
J2 - Proc. of IBIC2016, Barcelona, Spain, Sept. 13-18, 2016
C1 - Barcelona, Spain
T2 - International Beam Instrumentation Conference
T3 - 5
LA - english
AB - A requirement for top-off operations at the NSLS-II facility is at least 50mA stored ring current. The Stored Beam Current Monitor (SBCM) is part of the NSLS-II Personnel Protection System (PPS) that determines the storage ring current based on Pick-Up Electrode (PUE) readings. The SBCM selects the 500 MHz component of the PUE signal and downconverts it to about 2 MHz. The 2 MHz signal is rectified, averaged down to a bandwidth of 500 Hz, and compared to a threshold voltage equivalent to 55mA of stored beam. A redundant SBCM system was also constructed and these two systems must agree that the stored beam is above the threshold to enable top-off operations. The SBCM is also required to remain accurate over wide range of possible bunch patterns and bunch intensity distributions. Under normal conditions for top-off operations the SBCM measurement accuracy is about 1%. The SBCM was commissioned in 2015 as part of the Top-Off Safety System (TOSS) which is responsible for ensuring safe top-off operations at NSLS-II.
PB - JACoW
CP - Geneva, Switzerland
SP - 427
EP - 430
KW - operation
KW - storage-ring
KW - PLC
KW - monitoring
KW - diagnostics
DA - 2017/02
PY - 2017
SN - 978-3-95450-177-9
DO - 10.18429/JACoW-IBIC2016-TUPG38
UR - http://jacow.org/ibic2016/papers/tupg38.pdf