JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for MOPG10: BPM Stabiltiy Studies for the APS MBA Upgrade

TY - CONF
AU - Lill, R.M.
AU - Sereno, N.
AU - Yang, B.X.
ED - Schaa, Volker RW
TI - BPM Stabiltiy Studies for the APS MBA Upgrade
J2 - Proc. of IBIC2016, Barcelona, Spain, Sept. 13-18, 2016
C1 - Barcelona, Spain
T2 - International Beam Instrumentation Conference
T3 - 5
LA - english
AB - The Advanced Photon Source (APS) is currently in the preliminary design phase for the multi -bend achromat (MBA) lattice upgrade. Beam stability is critical for the MBA and will require long term drift defined as beam motion over a seven-day timescale to be no more than 1 micron at the insertion device locations and beam angle change no more than 0.5 micro-radian. Mechanical stability of beam position monitor (BPM) pickup electrodes mounted on insertion device vacuum chambers place a fundamental limitation on long-term beam stability for insertion device beamlines. We present the design and implementation of using prototype mechanical motion system (MMS) instrumentation for quantifying this type of motion specifically in the APS accelerator tunnel and experiment hall floor under normal operating conditions. The MMS presently provides critical position information on the vacuum chamber and BPM support systems. Initial results of the R&D prototype systems have demonstrated that the chamber movements far exceed the long-term drift tolerance specified for the APS Upgrade MBA storage ring.
PB - JACoW
CP - Geneva, Switzerland
SP - 55
EP - 58
KW - detector
KW - ground-motion
KW - diagnostics
KW - vacuum
KW - experiment
DA - 2017/02
PY - 2017
SN - 978-3-95450-177-9
DO - 10.18429/JACoW-IBIC2016-MOPG10