Author: Dong, Z.
Paper Title Page
TUP2WA04 Dynamic Vacuum Simulation for the BRing 186
 
  • P. Li, Z. Dong, M. Li, J.C. Yang
    IMP/CAS, Lanzhou, People's Republic of China
  • L.H.J. Bozyk
    GSI, Darmstadt, Germany
 
  Funding: Youth Innovation Promotion Association of Chinese Academy of Sciences 2016364, National Natural Science Foundation of China (Project No. 11675235).
Large dynamic vacuum pressure rises of orders of magnitude which caused by the lost heavy ions can seriously limit the ion intensity and beam lifetime of the heavy ion accelerator, especially for the machine that operate the intermediate charge state heavy ion. The High Intensity heavy ion Accelerator Facility (HIAF) which will be built by the IMP will accumulate the intermediate charge state ion 238U35+ to intensity 2*1011 ppp to different terminals. In order to control the dynamic vacuum effects induced by the lose beams and design the collimation system for the BRing of the HIAF, a newly developed simulation program (ColBeam) and GSI's simulation code StrahlSim are both conducted and the dynamic vacuum simulation result is calculated by the StrahlSim. According to the simulation result, 3*1011 ppp particles is the up limit beam intensity can be extracted for the current BRing vacuum system design. Higher beam intensity can be reach to 5*1011 ppp when the NEG coating technology must be implemented for the dipole and quadrupole chamber.
HIAF, Collimation, Dynamic vacuum
 
slides icon Slides TUP2WA04 [9.947 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-HB2018-TUP2WA04  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)