WE4P37 Laser Interferometer for Hall Probe Alignment and Measurement of Undulator 215
 
  • S.M. Khan, G. Mishra
    Devi Ahilya University, Indore, India
  • M. Gehlot
    DESY, Hamburg, Germany
  • S. Mishra
    Devi Ahilya Vishwa Vidyalaya, Institute of Engineering & Technology, Indore, India
 
  In the Hall probe Magnetic measurement method the field mapping is done along the length of the undulator. The field integral and phase error computed from the field mapping works as the figure of merit of the undulator. In this paper, we discuss the working of a laser interferometer for precise Hall probe alignment. A new user friendly software based on MATLAB has been developed. The phase error and magnetic field integrals are calculated for both taper and untaper U50 undulator of the Laser and Insertion Device Application (LIDA) Laboratory.  
DOI • reference for this paper ※ doi:10.18429/JACoW-FLS2023-WE4P37  
About • Received ※ 22 August 2023 — Revised ※ 22 August 2023 — Accepted ※ 31 August 2023 — Issued ※ 02 December 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WE4P38 Pulsed Wire Measurement of 20 mm Period Hybrid Undulator and Effects of Dispersion 218
 
  • S.M. Khan, G. Mishra
    Devi Ahilya University, Indore, India
  • M. Gehlot
    DESY, Hamburg, Germany
 
  In the pulsed wire method, a thin wire is stretched along the undulator axis with a sensor located near the undulator end. When a current flows through the wire, the Lorentz force on the wire sets up a travelling wave that is picked up by a sensor. Sensor output v. time gives the field integral v. position along the undulator length. We investigate pulsed wire measurements of field integrals and phase error of a 20 mm-period, 500 mm-long undulator and discuss variation in performance with Hall probe data, without any dispersion correction algorithm. Dispersion in the wire introduces dispersion corrected pulse lengths for the field integral measurements. Two field integrals of the undulator were measured with an accuracy close to 2 Gcm and 2 Gcm2 with the Hall probe result. The contributions of dispersion to the phase error of the undulator are analyzed. The dispersion assisted phase advance in the undulator in the pulsed wire is measured with a higher slope in comparison to the Hall probe data. Dispersion limited optical phase growth along the undulator length causes period length fluctuations and yields a discrepancy in the phase error computation in comparison to Hall probe data.  
DOI • reference for this paper ※ doi:10.18429/JACoW-FLS2023-WE4P38  
About • Received ※ 22 August 2023 — Revised ※ 22 August 2023 — Accepted ※ 31 August 2023 — Issued ※ 02 December 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)