Author: Sleziona, V.
Paper Title Page
TUP079 Status of the Hard X-Ray Self-Seeding Setup at the European XFEL 242
 
  • G. Geloni, S. Karabekyan, D. La Civita, L. Samoylova, S. Serkez, R. Shayduk, H. Sinn, V. Sleziona, M. Vannoni, M. Yakopov
    EuXFEL, Schenefeld, Germany
  • J.W.J. Anton, S.P. Kearney, D. Shu
    ANL, Lemont, Illinois, USA
  • V.D. Blank, S. Terentiev
    TISNCM, Troitsk, Russia
  • W. Decking, V. Kocharyan, S. Liu, E. Negodin, E. Saldin, T. Wohlenberg
    DESY, Hamburg, Germany
  • X. Dong
    European X-Ray Free-Electron Laser Facility GmbH, Schelefeld, Germany
 
  A Hard X-Ray Self-Seeding (HXRSS) setup will be soon commissioned at the European XFEL. It relies on a two-chicanes scheme to deal, in particular, with the high pulse repetition rate of the facility. In this contribution we review the physics choices made at the design stage and the expected performance of the setup. We will also focus on the description of the hardware installations made at the SASE2 line of the European XFEL.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2019-TUP079  
About • paper received ※ 27 August 2019       paper accepted ※ 28 August 2019       issue date ※ 05 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP079 Effect of Heat Load on Cryo-Cooled Monochromators at the European X-Ray Free-Electron Laser: Simulations and First Experimental Observations 502
 
  • I. Petrov, U. Boesenberg, M. Dommach, J. Eidam, J. Hallmann, K. Kazarian, C. Kim, W. Lu, A. Madsen, J. Möller, M. Reiser, L. Samoylova, R. Shayduk, H. Sinn, V. Sleziona, A. Zozulya
    EuXFEL, Schenefeld, Germany
  • J.W.J. Anton, S.P. Kearney, D. Shu
    ANL, Lemont, Illinois, USA
  • X. Dong
    SINAP, Shanghai, People’s Republic of China
  • X. Dong
    SARI-CAS, Pudong, Shanghai, People’s Republic of China
 
  European XFEL (EuXFEL) generates high-intensity ultra-short pulses at MHz repetition rate. At hard X-ray instruments, cryo-cooled silicon monochromators are used to reduce pulse bandwidth. Here, first experimental observations during commissioning of a cryo-cooled monochromator at Materials Imaging and Dynamics (MID) instrument are presented and compared with heat flow simulations. A thermal relaxation time is estimated and compared with arrival time interval between pulses. This provides the repetition rate tolerable for stable operation of monochromator.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2019-WEP079  
About • paper received ※ 19 August 2019       paper accepted ※ 25 August 2019       issue date ※ 05 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)