Author: Han, J.H.
Paper Title Page
WEP064 Performance of S-Band Photocathode RF Gun With Coaxial Coupler 481
 
  • J.H. Hong, J.H. Han, C.-K. Min
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  To improve the characteristics of electron beams, new S-band photocathode RF gun with a coaxial coupler has been developed and fabricated at the Pohang Accelerator Laboratory (PAL). This new RF gun is improved the field symmetry inside the cavity cell by applying the coaxial coupler, and the cooling performance by improving the cooling lines. The RF gun is installed in the injector test facility (ITF) for high power RF test. This paper reports the recent results on the RF conditioning process and the beam tests of the RF gun with high power RF at ITF. We present and discuss the measurement results of the basic beam parameters.  
poster icon Poster WEP064 [0.784 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2019-WEP064  
About • paper received ※ 24 August 2019       paper accepted ※ 26 August 2019       issue date ※ 05 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP092 Spare Undulator Production for PAL-XFEL HX1 Beamline 524
 
  • J.H. Han, Y.G. Jung, D.E. Kim, S.J. Lee
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  In the PAL-XFEL hard X-ray beamline, 20 undulator segments with a 26 mm period and a 5 m length are installed and operated for XFEL user service. One spare undulator was manufactured in December 2018. The magnetic measurements and tuning was carried out recently. We report the measurement and tuning results.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2019-WEP092  
About • paper received ※ 20 August 2019       paper accepted ※ 25 August 2019       issue date ※ 05 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP093 Radiation Damage Monitoring at PAL-XFEL 528
 
  • S.J. Lee, J.H. Han, Y.G. Jung, D.E. Kim, G. Mun
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  Pohang Accelerator Laboratory X-ray Free Electron Laser (PAL-XFEL) has two undulator beamlines, one hard and one soft X-ray beamlines. These two undulator beamlines are in operation since 2017. To maintain the FEL radiation property, the B-field properties of PAL-XFEL undulators need to be kept at certain level. Under the 10 GeV beam operation condition, the accumulated radiation can affect the permanent magnet properties of the undulators. However, the radiation damage of permanent magnet can be different by the operation environment and the geometry of the undulator. Accumulated radiation sensors and a miniature undulator with a few periods are installed in the PAL-XFEL hard X-ray undulator line to monitor the undulator radiation damage. In this proceeding, the radiation monitoring activities and the recent measurement results will be introduced.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2019-WEP093  
About • paper received ※ 19 August 2019       paper accepted ※ 25 August 2019       issue date ※ 05 November 2019  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)