Author: Gehlot, M.
Paper Title Page
WEP085 Field Integral Measurements of DAVV Undulators and Future Measurement Plan 513
 
  • M. Gehlot, S.M. Khan, R. Khullar, G. Mishra
    Devi Ahilya University, Indore, India
  • J. Hussain
    Department of Applied Physics, UIT, Bhopal, India
  • F. Trillaud
    UNAM, México, D.F., Mexico
 
  Funding: This work is supported by SERB-DST grant EMR/2014/00120 and financial support from UGC [F.15-1/2014-15/PDFWM-2014-15-GE-MAD-26801(SA-II)], Delhi and DGAPA of UNAM, fund PAPIIT TA100617
The Insertion device development and Application (IddA) laboratory of Devi Ahilya University, Indore, India has ongoing activities on undulator design and development. In this paper, we analyze the field integral properties of the two DAVV undulator. The first is the IddA U20 prototype NdFeB-cobalt steel hybrid in house designed device of 20 mm period length with twenty five periods. The uniform gap variable hybrid undulator provides magnetic flux density (in rms) from 2400 G to 500 G in the 10 mm to 20 mm gap range. The second is the NdFeB based U50II undulator of 50 mm period length with 20 number of periods. Hall probe results are described. A short description of the measurement plan of the undulator on the pulsed wire bench and stretched wire bench is described.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2019-WEP085  
About • paper received ※ 20 August 2019       paper accepted ※ 26 August 2019       issue date ※ 05 November 2019  