WED01 | Experience with Short-Period, Small Gap Undulators at the SwissFEL Aramis Beamline | 564 |
|
||
The SwissFEL Aramis beamline provides hard X-ray FEL radiation down to 1 Angström with 5.8 GeV and short period, 15 mm, in-vacuum undulators (U15). To reach the maximum designed K-value of 1.8 the U15s have to be operated with vacuum gaps down to 3.0 mm. The thirteen-undulator modules are 4 m long and each of them is equipped with a pair of permanent magnet quadrupoles at the two ends, aligned magnetically to the undulator axis. Optical systems and dedicated photon diagnostics are used to check the alignment and improve the K-value calibration. In this talk the main steps of the undulator commissioning will be recalled and a systematic comparison between the magnetic results and the electron and photon based measurements will be reported to highlight achievements and open issues. | ||
![]() |
Slides WED01 [13.825 MB] | |
DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2019-WED01 | |
About • | paper received ※ 28 August 2019 paper accepted ※ 06 November 2019 issue date ※ 05 November 2019 | |