WEB02 Wire-Scanners with Sub-Micrometer Resolution: Developments and Measurements 307
 
  • G.L. Orlandi, S. Borrelli, Ch. David, E. Ferrari, V. Guzenko, B. Hermann, O. Huerzeler, R. Ischebeck, C. Lombosi, C. Ozkan Loch, E. Prat
    PSI, Villigen PSI, Switzerland
  • N. Cefarin, S. Dal Zilio, M. Lazzarino
    IOM-CNR, Trieste, Italy
  • M. Ferianis, G. Penco, M. Veronese
    Elettra-Sincrotrone Trieste S.C.p.A., Basovizza, Italy
 
  Monitors of the beam transverse profile with ever more demanding spatial resolution and minimal invasivity are required by the FEL community. In order to improve the spatial resolution towards the sub-micrometer limit as well as to decrease the impact on the lasing process, nano-fabricated wire-scanners have been manufactured independently at PSI and FERMI by means of a lithographic technique [1,2]. Experimental tests carried out at SwissFEL at a low emittance demonstrated the capability of such innovative wire-scanner solutions to resolve beam transverse profiles with a size of 400-500 nm without being affected by any resolution limit. Status and outlook of nano-fabricated wire-scanners will be presented.
[1] M. Veronese et al., NIM-A, 891, 32-36, (2018).
[2] S. Borrelli et al., Comm. Phys.-Nature, 1, 52 (2018).
 
slides icon Slides WEB02 [11.196 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-FEL2019-WEB02  
About • paper received ※ 24 August 2019       paper accepted ※ 28 August 2019       issue date ※ 05 November 2019  