WEICCC004 First Results of Commissioning DC Photo-Gun for RHIC Low Energy Electron Cooler (LEReC) 65
 
  • D. Kayran, Z. Altinbas, D. Bruno, M.R. Costanzo, A.V. Fedotov, D.M. Gassner, X. Gu, L.R. Hammons, P. Inacker, J.P. Jamilkowski, J. Kewisch, C.J. Liaw, C. Liu, K. Mernick, T.A. Miller, M.G. Minty, V. Ptitsyn, T. Rao, J. Sandberg, S. Seletskiy, P. Thieberger, J.E. Tuozzolo, E. Wang, Z. Zhao
    BNL, Upton, Long Island, New York, USA
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy
Non-magnetized bunched electron cooling of ion beams during low energy RHIC operation requires electron beam energy in the range of 1.6-2.6 MeV, with an average current up to 45 mA, very small energy spread, and low emittance. A 400 kV DC gun equipped with a photocathode and laser system will provide a source of high-quality electron beams. During DC gun test critical elements of LEReC such as laser beam system, cathode exchange system, cathode QE lifetime, DC gun stability, beam instrumentation, the high-power beam dump system, machine protection system and controls has been tested under near- operational conditions [1]. We present the status, experimental results and experience learned during the LEReC DC gun beam testing.
[1] D. Kayran et al., DC Photogun Gun Test for RHIC Low Energy Electron Cooler (LEReC), NAPAC2016 proceedings, WEPOB54.
 
slides icon Slides WEICCC004 [20.774 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-ERL2017-WEICCC004  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)