Author: Ganis, G.
Paper Title Page
TUZAT0203 Machine Induced Backgrounds in the FCC-ee MDI Region and Beamstrahlung Radiation 85
 
  • A. Ciarma, G. Ganis, E. Perez
    CERN, Meyrin, Switzerland
  • M. Boscolo
    LNF-INFN, Frascati, Italy
 
  The new design for the central chamber of the FCC-ee beam pipe has a reduced radius of R=10mm and length of L=18cm, allowing to have the inner layer of the Vertex Detector Barrel closer to the interaction point. The effect of the background induced occupancy due to Incoherent Pairs Creation (IPC), beam losses in the MDI area and Synchrotron Radiation are explored for the CLD detector, using the updated version of the Vertex Detector for the new central beam pipe. Also, the characterisation of the intense Beamstrahlung radiation produced at FCC-ee is given.  
slides icon Slides TUZAT0203 [9.477 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-eeFACT2022-TUZAT0203  
About • Received ※ 28 November 2022 — Revised ※ 06 February 2023 — Accepted ※ 08 February 2023 — Issue date ※ 18 February 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)