A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Widger, D.

Paper Title Page
MOPP117 First Test of the Cornell Single-cavity Horizontal Cryomodule 835
 
  • S. A. Belomestnykh, E. P. Chojnacki, R. Ehrlich, R. P.K. Kaplan, M. Liepe, V. Medjidzade, D. Meidlinger, H. Padamsee, P. Quigley, J. J. Reilly, D. M. Sabol, J. Sears, V. D. Shemelin, E. N. Smith, V. Veshcherevich, D. Widger
    CLASSE, Ithaca
 
  A single-cavity horizontal test cryomodule (HTC) has been designed and fabricated recently at Cornell University for ERL project. This cryomodule is a shortened version of the full injector cryomodule, which will house five superconducting cavities. It serves as a test bench for new design features and for testing fully dressed two-cell ERL injector cavities. The cryostat design has been optimized for precise cavity alignment, good magnetic shielding, and high cryogenic loads from the RF cavities, input couplers, and HOM loads. The HTC was made long enough so in the future it can accommodate longer, multicell cavities of the ERL main linac. In this paper we report on results from the first full test of the HTC, including RF system and superconducting cavity performance, cryomodule studies and operation of a new 1.8 K cryogenic system.  
MOPP138 First Test Results from the Cornell ERL Injector Cryomodule 883
 
  • M. Liepe, S. A. Belomestnykh, E. P. Chojnacki, Z. A. Conway, R. Ehrlich, R. P.K. Kaplan, V. Medjidzade, H. Padamsee, P. Quigley, J. J. Reilly, D. M. Sabol, J. Sears, V. D. Shemelin, E. N. Smith, V. Veshcherevich, D. Widger
    CLASSE, Ithaca
 
  Cornell University has developed and fabricated a 5 cavity SRF injector cryomodule for the acceleration of a high current (100 mA), ultra low emittance beam. This cryomodule has been installed in the Cornell ERL prototype, and is presently under extensive test. The combination of a high beam current with emittance preservation of an ultra low emittance beam results in a multitude of challenges for the SRF system, pushing parameters well beyond present state of the art. Strong HOM damping and effective HOM power extraction is required to support the 100 mA beam current. This is achieved by placing HOM beam line absorbers between all cavities. Emittance preservation is addressed by a symmetric beam line with twin input couplers, tight cavity alignment and the option of fine alignment of cold cavities. In this paper we report on first results from the injector module test, including cavity performance tests, static heat load measurements and microphonic studies.