WEPC129 Undulator Demagnetization due to Radiation Losses at FLASH 2308
 
  • J. Skupin, B. Faatz, Y. Li, J. Pflueger, T. Vielitz
    DESY, Hamburg
 
  The free-electron laser FLASH was set up at DESY Hamburg in 2004. It is a high-gain, single pass FEL which operates in the VUV and soft X-ray wavelength regime. To monitor the demagnetization of the undulator structures due to radiation losses a small test undulator was installed. This dosimetric undulator (DU) consists of a short piece of magnetic undulator structure with only 3 pole pairs and corresponding magnets. It is positioned in front of the first undulator module where a high dose rate is to be expected. The accumulated dose of DU and undulator system is derived by weekly measurements with thermoluminescence dosimeters (TLDs). The DU is dismounted and magnetically measured regularly. Based on these measurements a (maximal) relative demagnetization rate of about 5*10-4/kGy was derived. In view of this result magnetic measurements on one of the undulators from TTF1 (the predecessor of FLASH) were reviewed. They show a relative demagnetization rate of about 2*10-4/kGy which is lower but still in the same range as the result from FLASH. FEL simulations to analyse the influence of the demagnetization on the SASE process are in progress.