A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Schlabach, P.

Paper Title Page
WEPC144 Test Results of the AC Field Measurements of Fermilab Booster Corrector Magnets 2347
 
  • J. DiMarco, D. J. Harding, V. S. Kashikhin, S. Kotelnikov, M. J. Lamm, A. Makulski, R. Nehring, D. F. Orris, P. Schlabach, C. Sylvester, M. Tartaglia, J. C. Tompkins, G. Velev
    Fermilab, Batavia, Illinois
 
  Multi-element corrector magnets are being produced at Fermilab that will enable correction of orbits and tunes through the entire cycle of the Booster, not just at injection. The corrector package includes six different corrector elements - normal and skew orientations of dipole, quadrupole, and sextupole - each independently powered. The magnets have been tested during typical AC ramping cycles at 15Hz using a fixed coil system to measure the dynamic field strength and field quality. The fixed coil is comprised of an array of inductive pick-up coils around the perimeter of a cylinder which are sampled simultaneously at 100kHz with 24-bit ADC’s. The performance of the measurement system and a summary of the field results are presented and discussed.