WEPC145 A Fast-sampling, Planar Array for Measuring the AC Field of Fermilab Pulsed Extraction Magnets 2350
 
  • J. DiMarco, C. Johnstone, O. Kiemschies, S. Kotelnikov, M. J. Lamm, A. Makulski, R. Nehring, D. F. Orris, A. D. Russell, M. Tartaglia, G. Velev, D. G.C. Walbridge, A. Yuan
    Fermilab, Batavia, Illinois
 
  A system employing a planar array of inductive pick-up coils has been developed for measurements of the rapidly changing dipole field in pulsed extraction magnets of the Fermilab MuCool project. The magnets are of C-type design, and have a peak field of 0.65 T during 8.33 millisecond half-sine pulse with 15 Hz repetition rate. The coils of the measurement system are fabricated on a single, 97.5 mm wide, 2-layer circuit board. The top layer of the circuit board has 15 unbucked coils distributed over its width. The bottom layer has a similar arrangement of coils, except each is bucked against the central winding to suppress the main dipole field and allow for more sensitive measurements of higher-order harmonics across the magnet mid-plane. The array of coils is simultaneously sampled at data rates of up to 100kHz with 10kHz bandwidth using 24-bit ADC’s. A detailed overview of the system and data analysis is presented, along with a characterization of results and system performance.