Paper | Title | Page |
---|---|---|
MOPC004 | First Results from the Upgraded PITZ Facility | 70 |
|
||
During autumn and winter 2007 a general reconstruction of the PITZ facility was performed. A new spectrometer based on a dipole magnet with 180 degree deflection angle was inserted in the facility. The new spectrometer contains two screen stations for the measuring of the longitudinal phase space and the slice emittance. A new "Conditioning Test Stand" (CTS) was added to the facility. Using this CTS a new electron gun having an improved cooling system is under conditioning. A new photocathode laser system (developed by MBI) was installed and commissioned. The goal is to reach rise and fall times of the laser pulses of 2 ps. The system of laser diagnostic was upgraded. The results reached using this upgraded facility are reported. This concerns the conditioning results of the new gun. Furthermore, a gun will be characterised using the new diagnostics beamline and the new photocathode laser. Results of the commissioning and first measurements of the new diagnostics components will be reported. |