A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Opanasenko, A.

Paper Title Page
MOPP100 Performance of Compact Electron Injector on Evanescent Oscillations 790
 
  • V. V. Mytrochenko, M. I. Ayzatskiy, I. V. Khodak, K. Kramarenko, V. A. Kushnir, A. Opanasenko, S. A. Perezhogin, D. L. Stepin, Z. V. Zhiglo
    NSC/KIPT, Kharkov
 
  An injector on the basis of a resonator structure with exponentially increasing amplitude of the electric field along an axis was developed at NSC KIPT. The injector is supplied with RF power through a rectangular-to-coaxial waveguide transition to provide axial symmetry of the accelerating field. The injector was designed to provide the output current up to 1 A at particle energy up to 1 MeV. Results of the injector test are presented in the work. Results obtained are compared with calculated ones.  
THPC027 Pulsed RF Accelerator of Electrons with Beam Recirculation 3038
 
  • V. V. Mytrochenko, M. I. Ayzatskiy, P. Gladkikh, V. A. Kushnir, A. Opanasenko, A. Y. Zelinsky
    NSC/KIPT, Kharkov
  • S. Chemerisov, D. Ehst
    ANL, Argonne, Illinois
 
  We discuss the project of upgrading existent 20 MeV L-band electron linac at Argonne National Laboratory aimed at electron energy increasing. It is shown that the proposed beam recirculation will provide on the accelerator output an electron beam with a pulse current 0.5 A and energy of particles 45 MeV. Problems of stability of recirculating beam are discussed.