Paper |
Title |
Page |
TUPC004 |
The Diagnostic Line of Elettra Booster 100MeV Pre-injector
|
1044 |
|
- S. Bassanese, L. Badano, M. Bossi, A. Carniel, G. Ciani, S. Di Mitri, M. Ferianis, G. Mian, G. Penco, M. Veronese
ELETTRA, Basovizza, Trieste
|
|
|
In order to fully characterize the beam of the new 100MeV linac pre-injector for the Elettra Booster, a standard diagnostic set-up has been designed which includes strip line BPMs, scintillating screens and current transformers. During the initial tuning of the pre-injector, a thermo-ionic gun followed by a 500MHz pre bunching cavity, an S-band bunching structure and two LIL accelerating sections, some extra diagnostics have been used to get a deeper understanding of the pre-injector operating point. In particular some prototypes of the FERMI@elettra diagnostics, installed on the same booster pre-injector, have been used to better characterize the beam transverse and longitudinal beam axis. An improved resolution screen system, equipped with a YAG screen, has been used as well as a wideband longitudinal pick-up. The measurement results as well as the tuning procedure are here presented.
|
|