A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Kazakevich, G. M.

Paper Title Page
TUPC047 Optical Transition Radiation Interferometry for the A0 Photoinjector 1164
 
  • G. M. Kazakevich
    BINP SB RAS, Novosibirsk
  • H. T. Edwards, R. P. Fliller, S. Nagaitsev, J. Ruan, R. Thurman-Keup
    Fermilab, Batavia, Illinois
 
  OTR interferometry (OTRI) is a promising diagnostic technique and was successfully developed and used for investigation of relativistic beams. For mid-energy accelerators the technique is traditionally based on thin polymer films (the first one is transparent for visible light) providing the beam multiple scattering of about 1 mrad or less. The disadvantage of these films is the unacceptable vacuum properties for photoinjectors and accelerators using superconducting cavities. We studied the application of thin mica sheets for OTRI diagnostics at the A0 Photoinjector in comparison with 2.5 μm thick Mylar films. This diagnostic is also applicable for the ILCTA-NML accelerator test facility that is planned at Fermilab. The experimental setups of the OTR interferometer for the A0 Photoinjector are described in the report. Results of simulations and measurements and comparison of the results obtained using Mylar and Mica-based interferometers are presented and discussed.  
THPC014 Investigation of Possible CSR Induced Energy Spread Effects with the A0 Photoinjector Bunch Compressor 3005
 
  • R. P. Fliller, H. T. Edwards, G. M. Kazakevich, J. Ruan, R. Thurman-Keup
    Fermilab, Batavia, Illinois
  • T. W. Koeth
    Rutgers University, The State University of New Jersey, Piscataway, New Jersey
 
  The bunch compressor of the A0 Photoinjector at Fermilab was removed this past spring to install a transverse to longitudinal emittance exchange experiment. Prior to its removal questions arose about the possibility of observing the effects of Coherent Synchrotron Radiation on the compressed beam. The energy spread of the beam with and without compression was measured to observe any changes. Various beam charges were used to look for square law effects associated with CSR. No direct observation of CSR was attempted because the design of the vacuum chamber did not allow it. In this paper we report the results of these experiments and comparison with simulations using ASTRA and CSRTrack. The results are compared with analytical approximations. The implications for the ongoing transverse to longitudinal emittance exchange experiment are discussed.