A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Gangini, F.

Paper Title Page
MOPD019 Construction and Quality Control of Synchrotron SOLEIL Beam Position Monitors 487
 
  • E. Cenni, M. Canetti, F. Gangini
    RIAL VACUUM S.p. A, Parma
  • J. L. Billaud
    Saint-Gobain C. R.E. E., Cavaillon
  • L. Cassinari, J.-C. Denard, C. Herbeaux
    SOLEIL, Gif-sur-Yvette
 
  SOLEIL is a third generation synchrotron light source located near Paris. Due to the high performance required for SOLEIL’s diagnostics, a special production procedure was tailored. During the production of 131 Beam Position Monitors (BPM) more than 500 feedthroughs were inspected; all of them passed strict tests at different stages of the production: Leak test (< 10-10 mbar l/s), Dimensional control (Displacement <0.050 mm), Vacuum test (Specific Outgassing < 10-12 mbar l/s cm2, Residual Gas Analysis) and Electrical test (Capacitance measure ~8pF, Insulation >50 MΩ, Impedance <0.1 Ω). All the established procedures and tests have been performed in a tight partnership that was more than a simple contractual framework, in which an intensive collaboration led to a knowledge transfer between SOLEIL and Rial Vacuum. The result has been a high percentage of success (few feedthroughs over 500 were replaced) during preliminary tests and a deeper knowledge of “BPM problem solving”; in this article are presented different test procedures to obtain high quality and high performance BPMs.