A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Cornelis, M.

Paper Title Page
MOPP097 Measurements on the Rf Cavity for the ALBA Storage Ring 781
 
  • M. L. Langlois, M. Cornelis, F. Pérez, P. Sanchez
    ALBA, Bellaterra
 
  ALBA storage ring will use 6 ambient temperature nose cone HOM damped cavities tuned at 500 MHz, designed at BESSY and known as the EU cavity. A first one, manufactured by ACCEL, was delivered in 2007 to investigate on its behaviour. This paper describes the data collected during investigation. First, bead-pull measurements were performed to assess impedance, both on fundamental and high order modes. Emphasis was put on E011, due to the discrepancy between expected values and results for this mode. The vacuum bake-out and related pressure are shown. Then, the cavity was conditioned and observations were made on multipacting levels, conditioning time and surface temperatures. The latter were found inhomogeneous and leads are detailed to avoid local overheating.