A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Chen, Z. C.

Paper Title Page
TUPC014 SSRF Injector Diagnostics Commissioning Results 1074
 
  • Y. Z. Chen, J. Chen, Z. C. Chen, Y. B. Leng, Y. B. Yan, W. M. Zhou
    SINAP, Shanghai
 
  This paper presents Injector beam diagnostics layout of the Shanghai Synchrotron Radiation Facility(SSRF) which includes the 150MeV LINAC, booster(3.5GeV) and beam transport lines. The different beam diagnostics monitors for beam current, beam position and beam profile are briefly described. The beam diagnostics data acquisition architecture is introduced. Commissioning Results of the 150Mev LINAC are presented, as well as the commissioning status of the booster .  
TUPC017 Beam Instrumentation System Development and Commissioning in SSRF 1080
 
  • Y. B. Leng, J. Chen, Y. Z. Chen, Z. C. Chen, G. Q. Huang, D. K. Liu, Y. B. Yan, K. R. Ye, C. X. Yin, J. Yu, L. Y. Yu, R. Yuan, G. B. Zhao, L. Y. Zhao, W. M. Zhou, Y. Zou
    SINAP, Shanghai
 
  In recent months the first beams have been stored in the Storage Ring of the Shanghai Synchrotron Radiation Facility (SSRF). The brief introduction will be given of the beam diagnostics system development. The initial commissioning results including beam profile monitors, beam position monitors (BPMs), DC current monitors (DCCT), and synchrotron radiation monitor (SRM) will be reported in this paper.