A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Bossi, M.

Paper Title Page
TUPC004 The Diagnostic Line of Elettra Booster 100MeV Pre-injector 1044
 
  • S. Bassanese, L. Badano, M. Bossi, A. Carniel, G. Ciani, S. Di Mitri, M. Ferianis, G. Mian, G. Penco, M. Veronese
    ELETTRA, Basovizza, Trieste
 
  In order to fully characterize the beam of the new 100MeV linac pre-injector for the Elettra Booster, a standard diagnostic set-up has been designed which includes strip line BPMs, scintillating screens and current transformers. During the initial tuning of the pre-injector, a thermo-ionic gun followed by a 500MHz pre bunching cavity, an S-band bunching structure and two LIL accelerating sections, some extra diagnostics have been used to get a deeper understanding of the pre-injector operating point. In particular some prototypes of the FERMI@elettra diagnostics, installed on the same booster pre-injector, have been used to better characterize the beam transverse and longitudinal beam axis. An improved resolution screen system, equipped with a YAG screen, has been used as well as a wideband longitudinal pick-up. The measurement results as well as the tuning procedure are here presented.