TUPCH055 Beam Phase Measurement of Stored Bunch 1133
 
  • T. Ohshima, A. Yamashita
    JASRI/SPring-8, Hyogo-ken
  • M. Yoshioka
    SES, Hyogo-pref.
 
  We developed a system to measure synchronous phase angles for all bunches stored in the storage ring using an oscilloscope with high sampling rate. Precise phase measurement of specific bunch is required from the synchrotron radiation (SR) users, especially from the time resolved spectroscopy users. In a pump and probe experiment, the trigger timing for pumping laser should be precisely adjusted to the probe SR light. The timing of SR light is affected by the accelerating RF voltages, filling pattern, bunch currents, gap positions of insertion devices and so on. At the SPring-8, the bunch currents and the synchronous phase angles for all stored bunches can be measured within 30seconds using newly developed system. The precision of the phase angle is less than 8ps. We are now preparing to deliver the information of synchronous phase angle to SR users. The detail of the measurement system and achieved performance will be presented.