A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Takashima, T.

Paper Title Page
TUPCH054 Upgrade of Signal Processing of the BPM System at the SPring-8 Storage Ring 1130
 
  • T. Fujita, S. Sasaki, M. Shoji, T. Takashima
    JASRI/SPring-8, Hyogo-ken
 
  SPring-8 is a third generation synchrotron light source, which is operated stably with top-up mode and with optics of low emittance mode. Along with stabilization of electron beam orbit in the ring, upgrading of the BPM system has also been required. We have developed a new signal processing circuit for COD measurement with a target of a few microns of position resolution at 1 kHz band-width and a few hundreds per second to take beam position of all BPMs. In the new circuit, a multiplexing method is employed and the IF frequency is directory detected with a 2MSPS 16-bit ADC. The digitized signal is processed with DSP to obtain beam position. Analog components of the circuit are equipped in a temperature controlled cabinet in order not to be affected by fluctuation of ambient temperature. In this paper we report schematics and performance of the new circuit, e.g., dependence of position resolution on measurement band-width and long time stability, etc. In addition, we briefly describe possibility of fast orbit measurement as a further application of the circuit.