|
- S.A. Belomestnykh, R.P.K. Kaplan, M. Liepe, P. Quigley, J.J.R. Reilly, C.K. Sinclair, V. Veshcherevich
Cornell University, Laboratory for Elementary-Particle Physics, Ithaca, New York
|
|
|
There are two high power 1300 MHz RF systms under development for the Cornell University ERL Injector. The first system, based on a 16 kWCW IOT transmitter, will provide RF power to a buncher cavity. The second system employs five 120 kWCW klystrons to feed 2-cell superconducting cavities of the injector cryomodule. All components of these systems were ordered and some have already been delivered, including the IOT transmitter (manufactured by Thales-BM), 20 kWCW AFT circulator, 170 kWCW circulators (Ferrite Co.) and two prototype input couplers for superconducting cavities. A special LN2 cryostat has been designed and built for testing/processing the input couplers. The results of the first high-power tests are presented.
|
|