Paper | Title | Page |
---|---|---|
MOPCH177 | Status of HOM Load for the Cornell ERL Injector | 478 |
|
||
The HOM load for the injector of the Energy Recovery Linac at Cornell University is proposed to work at a temperature of 80 K. The anticipated absorbed power of the load is up to 200 W. Versions with inner diameter of 78 and 106 mm are under development. Two different kinds of ferrites and a lossy ceramic are chosen as RF absorbers for the load to cover a wide frequency range. Measurements of electromagnetic properties of absorbing materials have been performed in a frequency range from 1 to 40 GHz. The engineering design of the load is ready and technological issues of brazing the absorbing tiles and cooling have been solved. Brazing quality is controlled by IR thermograms. First warm measurements of a prototype load are expected this summer. |