TUPCH015 Integrated Beam Diagnostics Systems for HICAT and CNAO 1028
 
  • A. Reiter, A. Peters, M. Schwickert
    GSI, Darmstadt
 
  An integrated system for beam diagnostics was produced at GSI for the heavy-ion cancer treatment facility HICAT of the Heidelberg university clinics. A set of 92 manifold beam diagnostic devices allows automated measurements of the main beam parameters such as beam current, profile or energy. The beam diagnostic subsystem is completely integrated in the overall accelerator control system and its timing scheme. This paper reports on the underlying design patterns for the abstraction of the beam diagnostic devices towards the control system. Event-counting devices, i.e. scintillating counters and ionization chambers, are presented as examples of the diagnostic devices in the synchrotron and high-energy beam transport section of HICAT. Additionally, it is shown that the well-defined building blocks of the beam instrumentation made it possible to prepare almost identical devices including the manual control software, to be used in the CNAO facility (Centro Nazionale di Adroterapia Oncologica) presently under construction in Pavia, Italy.