TUPCH014 Machine Protection by Active Current-transmission Control at GSI-UNILAC 1025
 
  • H. Reeg, J. Glatz, N. Schneider
    GSI, Darmstadt
  • H. Walter
    Ing.-Buero H. Walter, Saulheim
 
  Toroidal beam current transformers (BCT) are installed at dedicated locations along the UNILAC accelerator. They provide an output signal with a fixed transimpedance. Dedicated signal pairs from consecutive transformers drive differential integrator stations. If preset protection levels are exceeded due to beam charge loss during the macro-pulse, fast interlock signals are generated. The actual beam pulse is instantaneously truncated by a fast beam chopper, avoiding any thermal damage or radio-activation of machine components.
A new BCT macro-pulse selector/display is presently under construction, which will provide time structure observation of multiple UNILAC macro-pulses, as well as long-term data logging. The hardware is set up with PXI components from National Instruments, running a multi-client/server controller software under LabViewRT®. Offline-analysis of the accumulated BCT data is expected to improve the protection system's operation and reliability. An overview of the system layouts, technical details, and relevant operational results will be presented.