A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Parc, Y.W.

Paper Title Page
THPLS108 Performance Test of RF Photo-Cathode Gun at the PAL 3529
 
  • J.H. Park, J.Y. Huang, C. Kim, I.S. Ko, Y.W. Parc, S.J. Park
    PAL, Pohang, Kyungbuk
  • X.J. Wang
    BNL, Upton, Long Island, New York
 
  A RF photo-cathode (RF PC) gun with 1.6 cell cavity is installed for the fs-FIR (Femto-second Far Infrared Radiation) facility being built at the Pohang Accelerator Laboratory (PAL). A short, intense, and low emittance electron beams are produced by the RF PC gun. Performance test of the gun is done include the measurement of RF chraterizations such as a resonant frequency, a mode separation, and etcs. The diagnostics of the beam according to the beam parameters such as phase, charge, and energy, and emittance are done. In this article, we present the measurement results of the RF charaterizations and the beam parameter diagnostics of the RF PC gun at the PAL.