TUPCH078 BPM Design for the ALBA Synchrotron 1190
 
  • F. Pérez, A. Olmos
    ALBA, Bellaterra
  • T.F. Günzel
    ESRF, Grenoble
 
  ALBA is a 3 GeV, low emittance, 3rd generation synchrotron light source that is in the construction phase in Cerdanyola, Spain. Vertical beam sizes down to a few microns will require beam stabilities on the submicron level. The BPM has to be designed in order to provide reliable and accurate beam position readings. Simulation and computational codes have been used to optimise, for a given vacuum chamber dimension, the BPM design. The optimisation has taken into account the usual sensitivity and intrinsic resolution parameters, but as well, the wakefield loss factor of the buttons. Due to the small vertical vacuum chamber dimension and the high design current, the beam power deposited in the buttons is becoming a concern due to the thermal deformation effects that can introduce errors at the submicron level. A compromise between a higher intrinsic resolution from one side, and a low power deposited by the beam in the buttons from the other, define the final buttons dimensions.