THPLS109 Measurements and Diagnostics on the MAX Recirculator 3532
 
  • M. Brandin, B. Nelander, S. Werin
    MAX-lab, Lund
 
  The MAX Recirculator is a unique accelerator, a two-pass linac at 500 MeV, that operates as injector for three storage rings. Here are presented some discussions on measurments of beam parameters such as emittance, energy spread, and bunch length. We describe what measurements are done, by wich methods, results, and how they can be improved. Also, we make an analysis of What methods and hardware are needed to perform the measurements that can't be done with the equipment in place today.