THPCH172 Present Status of Beam Collimation System of J-PARC RCS 3200
 
  • K. Yamamoto
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken
  • M. Abe, H. Hanaue, A. Nakamura, Y. Takeuchi
    VIC International Co., Ltd., Tokyo
  • Y. Hirooka, M. Okazaki
    Mitsui Engineering & Shipbuilding Co., Ltd., Tokyo
 
  The precedence manufacture of the two beam collimator was carried out. In these two sets, we tested the heat transfer capacity of cooling fins and remote clamp handling system. The vertical collimator was able to keep temperature under 120 degrees C by the design heat 400W, but in case of the horizontal collimator, it went over 200 degrees C by the design heat 700W. The design was changed towards adding an air duct. About remote clamp handling system, it checked that it could attach by the He leak below 5.*10-10Pa m3/sec as a result of the helium leak examination.