WEPLS135 Piezoelectric Transformer Based Continuous-conduction-mode Voltage Source Charge-pump Power Factor Correction Electronic Ballast 2694
 
  • R.L. Lin, H.-M. Shih
    NCKU, Tainan city
  • C.-Y. Liu, K.-B. Liu
    NSRRC, Hsinchu
 
  This paper presents the piezoelectric transformer (PT) based continuous-conduction-mode (CCM) voltage source (VS) charge-pump (CP) power factor correction (PFC) electronic ballast. By replacing L-C resonant tank and transformer in the conventional CCM VS CP PFC electronic ballast with PT, the cost and volume can be reduced. The main drawback of conventional electronic ballast is that the input current has a narrow conduction angle, which causes rich harmonic that pollute the power system. However, the conventional CCM VS CP PFC electronic ballast is able to solve this problem but still require larger volume. Since the equivalent circuit of PT is identical to the conventional L-C resonant tank used in CCM VS CP PFC electronic ballast, the L-C resonant tank can be replaced by the PT to reduce the cost and volume. In addition, the inherent input capacitance of the PT works as a turn-off snubber for the power switches to decrease the turn-off voltage spikes and thus reduces the turn-off losses of the switches. The results show that the electronic ballast using PT achieved high power factor and the switches can be operated under ZVS condition.