A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Leigh, B.

Paper Title Page
WEPLS066 Harmonic Measurement and Adjustment of Diamond Quadrupoles 2532
 
  • C.P. Bailey, N. Marks
    Diamond, Oxfordshire
  • F. Goldie, B. Leigh
    Tesla Engineering Limited, West-Sussex
 
  The 254 quadrupole magnets for Diamond, manufactured by Tesla Engineering Ltd, were measured for harmonic content to a level around 1 part in 104. In order to meet the demanding requirements on field quality, procedures were then developed to adjust the relative positions of the magnet quadrants such that the desired harmonic levels were achieved. This process was integrated into the analysis software so that the needed changes were specified. The measurements were performed on a seven-coil rotating coil rig, which also enabled the alignment of the magnet in five spatial degrees of freedom to the specified accuracy. In this report we describe the measurement and correction procedures and present a summary of the results that were obtained.