TUPCH136 | Phase Measurement and Compensation System in PLS 2.5 GeV Linac for PAL-XFEL | 1337 |
|
||
In PAL, We are preparing the 3.7 GeV PALXFEL project by upgrading the present 2.5GeV Linac. In present PLS Linac, the specifications of the beam energy spread and rf phase are 0.6%(peak) and 3.5 degrees(peak) respectively. And the output power of klystron is 80 MW at the pulse width of 4 ? and the repetition rate of 10 Hz. In XFEL, the specifications of the beam energy spread and rf phase are 0.03%(rms) and 0.01 degrees(rms) respectively. We developed an analogue and a digital phase measurement and rf phase compensation system for stable beam quality. This paper describes the microwave system for the PALXFEL and the rf phase measurement and phase compensation system. |