A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Haeuser, J.

Paper Title Page
TUPLS038 The MAFF IH-RFQ Test Stand at the IAP Frankfurt 1577
 
  • A. Bechtold, D. Habs
    LMU, München
  • J. Fischbach, U. Ratzinger, J. Rehberg, M. Reichwein, A. Schempp
    IAP, Frankfurt-am-Main
  • J. Haeuser
    NTG Neue Technologien GmbH & Co KG, Gelnhausen
  • O.K. Kester
    GSI, Darmstadt
 
  The IH-type RFQ for the MAFF project at the LMU in Munich is presently under construction and will be integrated into a beam test stand at the IAP in Frankfurt. It is the second RFQ following the IH resonator concept and the first one that can be directly compared to a very similar 4-rod type machine, namely the REX-ISOLDE RFQ at CERN. The MAFF RFQ has been designed to accelerate rare isotope beams (RIBs) with mass to charge ratios up to 6.3 from 3 keV/u to 300 keV/u at an operating frequency of 101.28 MHz with an electrode voltage of 60 kV. First RF-measurements have already been executed and can be compared to appropriate simulation results. Parts of the test stand are currently under construction, such as the volume ion source for He+ at an extraction voltage of 12 keV and an electrostatic quadruplet for injection with an integrated steering system. These tests and accompanying theoretical investigations will be done with special respect to the applicability of such normal conducting RFQ accelerators to the EURISOL post accelerator.