WEPLS099 Fault Detection and Identification Methods Used for the LHC Cryomagnets and Related Cabling 2607
 
  • D. Bozzini, F. Caspers, V. Chareyre, Y. Duse, T. Kroyer, R. Lopez, A. Poncet, S. Russenschuck
    CERN, Geneva
 
  Several non-standard methods for electrical fault location have been successfully developed and tested. As part of the electrical quality assurance program, certain wires have to be subjected to a (high) DC voltage for the testing of the insulation. With the time difference of spark-induced electromagnetic signals measured with an oscilloscope, fault localization within a ± 10 cm range has been achieved. Another method used and adapted for the particular needs, was the synthetic pulse time-domain reflectometry (TDR) by means of a vector network analyzer. This instrument has also been applied as a low frequency sweep impedance analyzer in order to measure fractional capacities of cable assemblies where TDR was not applicable.