Duller, G.M.A.

Paper Title Page
WEPLS067 Magnets for the 3 GeV Booster Synchrotron for the Diamond Light Source 2535
 
  • S.P. Mhaskar, C.P. Bailey, G.M.A. Duller, V.C. Kempson, N. Marks
    Diamond, Oxfordshire
  • F. Bødker, N. Hauge, L.H. Helmersen
    Danfysik A/S, Jyllinge
 
  The Diamond Booster is a full energy injector for the Diamond Storage Ring. It is designed to accelerate electrons from 100 MeV to 3 GeV at a 5 Hz repetition rate. The lattice is a missing dipole FODO lattice consisting of 22 unit cells with 36 dipoles, 44 quadrupoles, 28 sextupoles and 44 correctors, distributed around a circumference of 158.4 m. The dipole field will be ramped from 0.026 T at injection to 0.809 T at 3 GeV; the quadrupoles will have a maximum operating gradient of 15T/m. The initial design of pole tip profiles was carried at Diamond, with the magnets then manufactured by DANFYSIK A/S as part of preassembled girder units (44 in total), complete with vacuum vessels. High quality was required to meet the accelerator physics requirements of alignment, positioning accuracies and field tolerances over the required good field apertures. Materials, ramp rates and field range have been selected to obtain almost linear response during magnet ramping. This paper describes the main features of the magnetic designs and measurement results; the magnets have now been delivered and installed at Diamond.  
THPLS029 Commissioning of the Booster Synchrotron for the Diamond Light Source 3344
 
  • V.C. Kempson, R. Bartolini, C. Christou, J.A. Dobbing, G.M.A. Duller, M.T. Heron, I.P.S. Martin, G. Rehm, J.H. Rowland, B. Singh
    Diamond, Oxfordshire
 
  The Diamond booster is a 158 m circumference, 5 Hz synchrotron which accelerates the 100 MeV electron beam from a linac to 3 GeV for full-energy injection into the Diamond storage ring. The booster has been commissioned in the first few months of 2006, following successful initial 100 MeV trials at the very end of 2005. The injection and ramping process, orbit correction and essential beam physics measurements are discussed as are extraction and beam transport to the storage ring.