WEPLS098 Experience with the Quality Assurance of the Superconducting Electrical Circuits of the LHC Machine 2604
 
  • D. Bozzini, V. Chareyre, K.H. Mess, S. Russenschuck
    CERN, Geneva
  • A. Kotarba, S. Olek
    HNINP, Kraków
 
  The coherence between the powering reference database and the Electrical Quality Assurance (ELQA) is guaranteed on the procedural level. However, a challenge remains the coherence between the database, the magnet test and assembly procedures, and the connection of all superconducting circuits of the LHC. In this paper, the methods, tooling, and procedures for the ELQA during the assembly phase of the LHC will be presented in view of the practical experience gained in the LHC tunnel. The parameters measured at ambient temperature such as the dielectric insulation and the impedance transfer function of assembled circuits will be discussed. Some examples of detected polarity errors and the treatment of non-conformities will be presented.  
WEPLS099 Fault Detection and Identification Methods Used for the LHC Cryomagnets and Related Cabling 2607
 
  • D. Bozzini, F. Caspers, V. Chareyre, Y. Duse, T. Kroyer, R. Lopez, A. Poncet, S. Russenschuck
    CERN, Geneva
 
  Several non-standard methods for electrical fault location have been successfully developed and tested. As part of the electrical quality assurance program, certain wires have to be subjected to a (high) DC voltage for the testing of the insulation. With the time difference of spark-induced electromagnetic signals measured with an oscilloscope, fault localization within a ± 10 cm range has been achieved. Another method used and adapted for the particular needs, was the synthetic pulse time-domain reflectometry (TDR) by means of a vector network analyzer. This instrument has also been applied as a low frequency sweep impedance analyzer in order to measure fractional capacities of cable assemblies where TDR was not applicable.