A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Ankenbrandt, C.M.

Paper Title Page
TUPCH147 High Pressure RF Cavities in Magnetic Fields 1364
 
  • P.M. Hanlet, M. Alsharo'a, R. E. Hartline, R.P. Johnson, M. Kuchnir, K. Paul
    Muons, Inc, Batavia
  • C.M. Ankenbrandt, A. Moretti, M. Popovic
    Fermilab, Batavia, Illinois
  • D.M. Kaplan, K. Yonehara
    Illinois Institute of Technology, Chicago, Illinois
 
  A study of RF breakdown in pressurized cavities immersed in strong magnetic fields has begun as part of a program to develop RF cavities filled with dense hydrogen gas to be used for muon ionization cooling. A pressurized 805 MHz test cell is being used at Fermilab to compare the conditioning and breakdown behavior of copper, molybdenum, and beryllium electrodes as functions of hydrogen and helium gas densities and magnetic field strength. These results will be compared to the predicted or known RF breakdown behavior of these metals in vacuum with and without external magnetic fields.